weblogic报错BEA-170011和BEA-000386
来源:网络收集 点击: 时间:2024-02-23步骤一:如图,重启weblogic受管理节点,出现报错BEA-170011和
BEA-170011 The LogBroadcaster on this server failed to broadcast log messages to the admin server. The Admin server may not be running. Message broadcasts to the admin server will be disabled.
.....
Feb 12, 2020 11:47:51 AM CST Critical WebLogicServer BEA-000386 Server subsystem failed. Reason: java.lang.SecurityException: Anonymous attempt to get to a JNDI resource
java.lang.SecurityException: Anonymous attempt to get to a JNDI resource
at weblogic.management.remote.common.ClientProviderBase.makeConnection(ClientProviderBase.java:194)
at weblogic.management.remote.common.ClientProviderBase.newJMXConnector(ClientProviderBase.java:84)
at javax.management.remote.JMXConnectorFactory.newJMXConnector(JMXConnectorFactory.java:338)
at javax.management.remote.JMXConnectorFactory.connect(JMXConnectorFactory.java:247)
at weblogic.management.mbeanservers.runtime.internal.RegisterWithDomainRuntimeService.getDomainMBeanServerConnection(RegisterWithDomainRuntimeService.java:222)
Truncated. see log file for complete stacktrace

步骤二:检查环境,管理节点控制台可以正常登陆,根据报错,感觉像管理节点和被管节点无法正常通信,但购歌是管理节点重启后,此报错仍然存在。

步骤三:查看资料,需要为管理节点和被管节点服务器配置监听地址。
登录控制台,环境撤矿海》服务器-点击对应的服务器,如图进入管理节点服务器配置

步骤四:如图,管理节点的监听地址没有配置,点击左侧锁定并编辑,填写对应的监听地址,保存并激活。


步骤五:重启管理节点让配置生效,最后重启被管节点,服务正常启动了。如果还有问题,检查下其他央泥服务器是否配置对应的监听地址。

每次解决问题都是自我成长的过程,不惧挑战,不怕困难
喜欢记得关注我哦
WEBLOGICBEA000386BEA170011管理节点被管节点版权声明: